THD, IMD, and Why 0.01% at 1kHz Tells You Almost Nothing

Views: 0     Author: Site Editor     Publish Time: 2026-11-22      Origin: Site

Inquire

Key Takeaways

  • THD measures what a single sine wave picks up passing through the amplifier: harmonics that were never in the input. THD+N adds the noise floor — the more honest figure.

  • A distortion number is meaningless without four conditions attached: frequency, power, load, bandwidth.

  • The spec-sheet favorite — 1 kHz, low power, resistive load, narrow bandwidth — is the easiest point on the entire distortion surface. The same amplifier can measure an order of magnitude worse at 20 kHz and full power.

  • IMD stresses linearity harder than THD. Intermodulation products share no harmonic relationship with the music, so nothing masks them — the same percentage sounds noticeably worse.

  • Crossover distortion and transient intermodulation distortion (TIM) hide from every steady-state single-point figure. Sweeps, multi-level tests and dedicated methods expose them.

The Short Answer

A distortion number only means something when four conditions travel with it: which frequency, at what power, into what load, over how wide a bandwidth. A single-point 0.01% at 1 kHz is the flattest spot on the curve — quoted alone, it describes the marketing, not the amplifier.

What THD Actually Measures

The method is disarmingly simple. Feed the amplifier one pure sine wave at frequency f₀ and look at what comes out. Real output devices are nonlinear, so the output contains not only f₀ but 2f₀, 3f₀ and beyond — harmonics the input never contained, manufactured by the circuit itself. Notch out the fundamental, sum the remaining energy, divide by the fundamental amplitude.

The percentage hides what matters most, because harmonics are not equal:

Harmonic

Order

Relation to the original note

Audibility at the same level

2nd, 4th

Even

Octaves — musically consonant

Mild; can read as "coloration"

3rd

Odd

A twelfth — dissonant interval

Hard, gritty edge

5th and higher

Mostly odd

Far from any musical interval

Harsh; much lower audibility threshold

Audibility ranking is general industry knowledge; level and program material shift it.

Two amplifiers can both print 0.1% — one dominated by low-order even harmonics, one by high-order odd harmonics — and sound entirely different. THD compresses the composition of the distortion into one number and discards the most important information.

Multichannel power amplifier front panel with heat-sink fins (illustrative only)

Typical multichannel amplifier construction (illustrative only)

THD+N: The N Is the Honest Part

THD counts harmonics only; THD+N sweeps the entire noise floor into the same figure. That single letter makes the test far harder to flatter. A design can shine on harmonics alone, but elevated hiss, supply ripple or switching residue show up immediately in THD+N — which is why serious specifications state THD+N, not THD.

The second hidden variable is bandwidth. Noise is broadband, so integrating to 22 kHz versus 80 kHz produces very different numbers; Class D switching residue lives above the audio band, and a wider window pulls it in. A properly stated figure looks like this: "THD+N < 0.05%, 20 Hz–20 kHz, 1/8 rated power, 8 Ω, 80 kHz bandwidth." Frequency, power, load, bandwidth — all four, every time.

Same 0.01%, an Order of Magnitude Apart

Distortion is not a constant. It is a function of power, frequency and load, and the spec-sheet point sits in the lowest valley of that three-dimensional surface:

Condition set

Position on the distortion surface

Typical relative level

1 kHz / 1 W or 1/8 rated / 8 Ω resistive / 22 kHz BW

The valley floor

0.005–0.01% (the spec-sheet favorite)

20 kHz / full power / 4 Ω / 80 kHz BW

The hardest corner

An order of magnitude higher is not unusual

Low level, below 1 W, Class AB

Crossover-exposure region

Where low-volume listening degrades first

Approaching clipping

The steep wall

Rapid collapse; protection circuits engage

Industry-typical magnitudes; architecture and design quality vary widely.

The physics behind the shape is well understood. Negative feedback suppresses distortion in proportion to loop gain, and loop gain falls with frequency — a Class AB stage may have only a fraction of its 1 kHz loop gain at 20 kHz. The low-frequency end stresses the power supply with large excursions, and a 4 Ω load doubles output current, pushing devices further from their linear region. Quoting the valley while ignoring the surface is not a specification.

Three Curves Worth Asking For

Axis

Typical behavior

What drives it

What a buyer should request

Power

Slight rise at low level, flat mid-range, steep climb near clipping

Output-stage bias and supply headroom

THD vs power curve; how far the knee sits from rated power

Frequency

Minimum near 1 kHz, rising at 20 Hz and 20 kHz

Loop gain falling with frequency; output inductor

THD vs frequency curve; how much 20 kHz rises

Load

Worse into 4 Ω than 8 Ω

Doubled current, tighter device operating points

The 4 Ω figure, not just 8 Ω

There is a fourth curve the spec sheet never mentions: temperature. Output-stage bias drifts as the amplifier heats, so a design with poor thermal tracking can measure noticeably worse after an hour of music than it did cold. Type testing therefore repeats distortion runs after thermal soak — and a buyer who asks "cold or at thermal steady state?" immediately learns how deep the validation goes.

Why IMD Predicts Listening Better Than THD

Real music is never one sine wave; it is dozens of frequencies sounding at once. Put two tones, f₁ and f₂, through a nonlinear circuit and the output sprouts f₂−f₁, f₂+f₁, 2f₁−f₂ and beyond — intermodulation products with no harmonic relationship to the music. They do not land on octaves or fifths; nothing masks them; they are heard as the gritty, blurred veil when complex material falls apart. The industry's comparative verdict is consistent: at the same percentage, IMD is more audible than THD.

One geometric detail is worth memorizing: third-order intermodulation products grow 3 dB for every 1 dB of signal — the fundamental gains 1 dB while the IM3 products gain 3. Distortion climbs steeply toward overload, and IMD near rated power says far more about real linearity than any low-level single-tone figure.

Masking completes the argument. A harmonic sits on top of its own note and is partially hidden by it; an intermodulation product sits in empty spectral space with nothing to hide behind. That is why two amplifiers with near-identical spec sheets can separate sharply on full orchestral material — music tests multi-tone intermodulation, not single-tone purity.

SMPTE, CCIF, DIN: Three Tests, Three Different Exams

Method

Signal

Amplitude ratio

Products measured

What it exposes

SMPTE (RP120)

60 Hz + 7 kHz

4:1

Sidebands at 7 kHz ±60/±120 Hz

Supply and gain stability under large low-frequency swings

CCIF / ITU-R twin tone (IEC 60268-3)

19 kHz + 20 kHz

1:1

1 kHz difference tone; 18k/21k third-order pair

High-frequency small-signal linearity — the 1 kHz product lands in the ear's most sensitive region

DIN (45403)

250 Hz + 8 kHz

4:1

Sidebands at 8 kHz ±250/±500 Hz

Mid-band modulation behavior

Method definitions follow SMPTE RP120, DIN 45403 and IEC 60268-3.

Percentages from different methods are not comparable — signal, ratio and arithmetic all differ, so the first question about any IMD figure is "which method, at what level," and only the second is "how much." SMPTE stresses the big-signal low-frequency path; CCIF stresses high-frequency small-signal behavior and applies equally to converters and preamps. Together they approximate real program material far better than any single-tone THD figure.

Crossover Distortion and TIM: The Failures a Single Point Cannot See

Two distortion mechanisms evade the spec-sheet point entirely, and both correspond to familiar field complaints.

Crossover distortion comes from the small discontinuity where a Class AB push-pull output stage hands signal between its upper and lower devices. It produces high-order odd harmonics and grows relatively worse as level falls — undersized, dry, constricted sound at low volume is its signature. A 1 kHz figure near rated power averages right over it; catching it requires low-level measurements and the harmonic spectrum.

Transient intermodulation distortion (TIM) belongs to deep feedback designs. The loop needs time to return its correction signal, and on fast transients the input stage can overload for an instant before correction arrives. Steady-state sine waves never exercise this, which is why dedicated square-wave-plus-sine methods exist. The diagnostic clue is direct: excellent steady-state figures but percussion that sounds late and blunted — suspect transient behavior and ask for square-wave response data.

When the Measurement Chain Lies

The instruments can contribute distortion of their own, and the number on the screen may describe the bench, not the device.

Stage

Common trap

Consequence

Standard practice

Signal source

Source distortion not low enough

Measuring the generator's harmonics

Source residual at least an order below the DUT limit

Load

Resistive dummy load versus a real speaker's impedance curve

Reactive behavior stays invisible

Dummy load per-unit; real and capacitive loads in type testing

Grounding

Ground loops injecting mains hum

Elevated noise floor inflating THD+N

Single-point grounding, shielded wiring, measure noise first

Analyzer

Overload or wrong range

Instrument's own IMD mixed into the result

Verify attenuation and range; re-test implausibly good numbers

Standard measurement practice, summarized.

The last row deserves emphasis: a result too good to be true can be a cancellation artifact. Measurement discipline shows up not as beautiful numbers but as conditions, instruments and repeat runs offered unprompted.

How a Factory Tests It: Per-Unit Versus Type Testing

Distortion lives on two tiers in production, with different purposes and different coverage:

Tier

What is checked

How (standard practice)

Records

Per-unit, on the line

Distortion and signal-to-noise at rated conditions, gain matching, protection functions

Audio analyzer plus power dummy-load banks, unit by unit

Per-unit records on file, with pass limits

Type testing

Full THD vs frequency and THD vs power sweeps; SMPTE and CCIF IMD; re-test after thermal soak

Design validation and first-article stages; real and capacitive loads included

Type reports on file, conditions complete

The split is deliberate industry practice: per-unit testing proves this unit is right; type testing proves this design and this batch are right. Buyers should require both. Per-unit records without type reports suggest thin design validation; type reports without per-unit records suggest the production line never closed the loop. On the floor, the per-unit station usually sits beside burn-in and safety-test stations, each unit bound to its serial number and record — one day's records for a random unit reveal more than any stack of summary spreadsheets.

Amplifier rear panel with per-channel inputs and outputs (illustrative only)

Typical rear panel channel I/O (illustrative only)

What to Ask, and What Evidence to Expect

A credible distortion figure carries five fields: frequency (or band), power or level, load impedance, measurement bandwidth and weighting, and the metric itself — THD or THD+N, and for IMD, which method. Missing any one is grounds to ask for a supplement. The questions follow:

Ask

Evidence to request

Answers that should worry you

Under what conditions is distortion rated?

Spec sheet matching the test record

A bare percentage with no conditions

Do you have THD vs frequency and vs power curves?

Type-test report showing 20 kHz and low-level regions

Only the 1 kHz single point

Which IMD method, at what level?

SMPTE and CCIF data, both

Cannot name the method

What is tested per unit on the line?

Sample per-unit records from a current model

Distortion absent from per-unit tests

How are bandwidth and weighting defined?

Analyzer settings or record screenshots

THD+N quoted with no bandwidth stated

Common Misconceptions

  • "Lower THD always sounds better." Below roughly 0.1%, low-order harmonic distortion is broadly inaudible on music; the composition matters more than the total.

  • "0.005% beats 0.01%." Only under identical conditions. A 0.005% at 1 kHz/1 W can lose to a 0.01% at 20 kHz/full power in every way that matters.

  • "Good THD means good linearity." IMD examines a different linear dimension, and steady-state tests never see TIM. All three views are needed.

  • "Class D looks worse wideband, therefore it's inferior." Switching residue sits above the audio band; under the 20 Hz–20 kHz convention most competent designs pass comfortably. Read the curve, not the fear.

  • "Distortion is a lab metric; production needn't test it." Per-unit distortion and S/N testing is the gate that carries the design figure onto each shipped unit; without it, type report and delivery have no evidence chain between them.

FAQ

Q1: Under what conditions is the spec-sheet 0.01% measured? Always ask. Standard practice states frequency, power (commonly 1/8 rated or 1 W), load and bandwidth. A large number with conditions attached deserves attention; a bare one does not.

Q2: Should I read THD or THD+N? Prefer THD+N — the noise floor is included, which makes the figure harder to flatter — and always confirm the bandwidth, since 22 kHz and 80 kHz windows can differ visibly.

Q3: Why does an amplifier with excellent specs sound congested on complex music? A steady-state single-point THD covers neither intermodulation nor transient behavior; both live outside that number. Ask for SMPTE/CCIF IMD and transient test data.

Q4: What is the minimum distortion review in a factory audit? Three items: spec-sheet conditions matching the test records; type-test THD curves and IMD data; and per-unit production records with pass limits for a current model.

Q5: How should Class D distortion be evaluated? Under the 20 Hz–20 kHz convention, with a bandwidth wide enough to cover switching residue (commonly 80 kHz), and with attention to the output filter and feedback architecture — the two decisions that set wideband linearity in Class D.

Four-channel amplifier front panel (illustrative only)

Typical four-channel amplifier front panel (illustrative only)

Closing

Three sentences carry the engineering meaning of distortion specifications. Every distortion figure is a sample from a surface defined by frequency, power, load and bandwidth — a single valley point carries no information. THD differs from THD+N by the noise floor, and both differ from IMD in the question asked: whether the added frequencies share any harmonic relationship with the music, which is why IMD tracks listening better. Crossover distortion and TIM sit outside every steady-state single point; low-level spectra, two-method IMD and transient tests cover the blind spots. For buyers, the executable version is short: treat five complete fields as the passing grade for any distortion figure, and write THD curves, SMPTE/CCIF IMD and per-unit records into the audit list — turning a pretty spec-sheet number into evidence traceable unit by unit.

To see the stations and instruments behind these tests, start with the test stations and instruments photographed on our factory floor; our collected notes on measurement and quality control live in our notes on amplifier measurement and quality control; and the product lines these test conventions apply to are listed in the multichannel amplifier and speaker lines currently in production.

CAMMICA delivers premium audio technology solutions for global brands, offering innovation‑driven engineering from Shenzhen, China.

Quick Links

Contact Information

 Address: Maschmuhlenweg 40-42     37037 Gottingen, Germany
 Add:  RM1506, Donghuayuan, Donghuanyilu, Longhua, Shenzhen, Guangdong, China
 
Contact Us
Copyright © 2026 ~2027  CAMMICA Technology Co., Ltd. All rights reserved. Sitemap Privacy Policy